Benefon TWIG INBOX Manuale Utente Pagina 35

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 107
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 34
MPTP | MPTP commands 35
Command format
Length: 14…22 characters
Command*
Trigger type
Service state
Interval
(Limit)
Unused
(Allowed value)
Number
of reports
(Trigger special data)
4 1 1 1 1 1 1…5 1 1 1 1…5
?TRG _ 1 _ 1 _ 30 _ 0 _ 20
*) cf. section 3.1 for description of this field.
The special fields of the command are as follows:
Field Description Range
Trigger type Trigger type of complex tracking request
message, as defined in section 4.2.1.4. In
this case, the trigger type number is 1.
0…9
Service state
Activity of tracking process. Value 1 should
be used; otherwise the process will not be
activated.
0…1
Interval Time between sending of tracking reports, in
minutes.
1…65534 (min)
Unused This field has been reserved for future use. For
now, value 0 should be used.
0
Number
of reports
Stop trigger condition: the tracking process is
stopped when the specified number of reports
have been sent.
1…65534
4.2.1.4.3. Trigger type 2: stopping at time limit
CC MTT
A type 2 tracking process sends reports at regular intervals for a specified time. Such a process can be
created and activated by a Control Centre, by sending a complex tracking request command with trigger
type 2.
The tracking process has the following properties:
Start trigger : None.
The tracking process is started as soon as it is created.
Interval
The process will send tracking reports at the specified interval until the stop trigger condition is
met. The interval is given in full minutes.